Chapter 4: Administration Introduction 45
The following table shows the fields for configuring sensor alarms.
See Configuring Sensor Alarms on page 93 for how to configure sensor alarms through the Web
Manager. See sensoralarm on page 161 for cli command instructions.
Target Device Configuration
When connecting devices to the SP manager, observe the following recommendations, as shown in
Figure 4.1:
Connect the dedicated Ethernet port on each device to one of the SP manager’s private
Ethernet ports.
Connect the main Ethernet port(s) on target devices to a production network.
Connect the SP manager’s primary Ethernet port (eth0) to a local management network and
usually to the Internet.
CAUTION: If a device has a single Ethernet port, that port would need to be attached to the production network,
and the SP manager would need to be configured to communicate with the device over the production network.
With this type of configuration, the SP manager would be unable to provide the same level of secure access to
devices that it provides when it is configured as recommended.
Figure 4.1 illustrates connecting two servers that have SPs, with the SPs indicated by gray boxes.
The same recommendations apply to connecting devices that do not have SPs but that have
dedicated Ethernet ports that provide access to the devices’ consoles.
Table 4.14: Values for Configuring Sensor Alarms
Values Description
Device Choose from a list of all target device.
Sensor The literal string for the sensor (which can be obtained from the sensor logs from the target
device), for example, Sys Fan 1.
Condition Trigger when value is >INSIDE< range.
Trigger when value is <OUTSIDE> range.
Trigger when value CHANGES.
Range Applies to the INSIDE and OUTSIDE conditions. The low and high thresholds can be any numeric
value, including floats. For example, for a fan whose average reading is 1470 RPR, you might
want to specify a low threshold of 1000 and a high threshold of 1600.
Interval A polling interval chosen by the administrator: a time in minutes or hours.
Action Syslog message trap.
Pager.
•Email.
Comment Any desired comment to identify the source of the alarm.